SAR airline with auxSo what is the Assigned-Protection Factor (APF) for an air-line respirator, commonly used inside PRCSs which has, or has the potential to have an IDLH atmosphere?  Is it 1,000 or 10,000? 

I have always been taught/trained that the simple air-line respirator (Pressure-demand/Positive pressure mode) WITHOUT the Auxilary/Back-up cylinder the APF is 1,000, but the addition of the Auxilary/Back-up cylinder then makes it "acceptable" for entry/work within an IDLH atmosphere with an APF of 10,000. But to show that we can always learn in this profession, I had to ask my FaceBook Group what a "combination respirator (e.g., airline respirators with an air-purifying filter)" is.  Luckily one of the members just happens to be a CIH and he did some digging and came up with a "combination respirator (e.g., airline respirators with an air-purifying filter)" so now we at least know what it looks like and why it gets an assigned protection factor of 1,000 (as shown in the red box below).  So what does OSHA mean when it says... (emphasis by me)

1910.134(d)(3)(i)(A) Assigned Protection Factors (APFs)

Employers must use the assigned protection factors listed in Table 1 to select a respirator that meets or exceeds the required level of employee protection. When using a combination respirator (e.g., airline respirators with an air-purifying filter), employers must ensure that the assigned protection factor is appropriate to the mode of operation in which the respirator is being used.

 
View 's profile on LinkedIn

 

 LinkedIn Group Button

facebookIcon

 

Partner Organizations

 Chlroine Institute Logo 100 years

I am proud to announce that

The Chlorine Institute and SAFTENG

have extended our"Partners in Safety" agreement

for another year (2024)

CI Members, send me an e-mail

to request your FREE SAFTENG membership

 

RCECHILL BW

  

kemkey logo

OHS Solutions logoCEMANE power association logo

 EIT LOGO

 

Member Associations

ASME logo

 

Screen Shot 2018 05 28 at 10.25.35 PM

aiche logo cmyk highres

Chlorine institute

 nfpa logo.5942a119dcb25

 

TOCAS

 

BLR Logo 2018

 

 

 

 

safteng man copy

 

 organdonor