Top 10 errors using Flame-Resistant Clothing (FRC) for flash fire protection

Using NFPA 2113 as our RAGAGEP, these items are by far the most common errors we find in our work when FRC is worn in flammable/HAZLOCs work areas:

(emphasis by me)

  1. Garments shall be selected that cover BOTH the UPPER AND LOWER BODY and flammable underlayers as entirely as possible.
  2. Non–flame-resistant heraldry attached to the exterior of the garment (e.g., logos, name tags, non-flame resistant silk-screened artwork, etc.) shall be kept to a MINIMUM, BOTH IN SURFACE AREA AND NUMBER.
  3. Flame-resistant garment COLLARS SHALL BE WORN CLOSED.
  4. SLEEVES AND CUFFS shall be worn DOWN AND SECURED.
  5. When a shirt and pair of trousers, both flame-resistant, are worn together, the SHIRT SHALL BE TUCKED IN.
  6. FLAME-RESISTANT OR NONMELTING UNDERGARMENTS (closest to the skin) shall be used.  An incidental amount of elastic used on non-melting fabric underwear or socks shall be permitted.
  7. Flame-resistant garments CONTAMINATED BY FLAMMABLE SUBSTANCES, hazardous materials, or biological agents shall be cleaned and decontaminated per manufacturer instructions.
  8. The organization shall develop a SYSTEMATIC INSPECTION PROGRAM for ALL FLAME-RESISTANT GARMENTS to confirm their serviceability.
  9. DAMAGED FLAME-RESISTANT GARMENTS shall immediately be removed from service.
  10. All repairs and alterations to flame-resistant garments shall be performed in the SAME MANNER AND USING THE SAME MATERIALS AS THE MANUFACTURER.

And here is one we see when contractors are using “disposable” FRC…

  1. Flame-resistant garments shall be RETIRED WHEN THEY EXCEED THE MANUFACTURER-STATED SERVICE LIFE if indicated.