Equipment Opening gone bad (System Applicator)

At 3:10 p.m. on February 2, 2022, an employee, 26, was performing maintenance on a System Applicator. The employee began the ammonia bleeding procedure wearing safety glasses and rubber gloves. After approximately 20 to 30 minutes, the employee no longer heard a whistling sound and believed that the system was completely bled out. When the employee removed the filter cap, the remaining anhydrous ammonia in the system was sprayed onto the employee. The employee was hospitalized for the treatment of chemical burns to the face, mouth, neck, and right forearm.

Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2         2
Current Violations       1   1
Initial Penalty $14,630 $0 $0 $0 $0 $14,630
Current Penalty $0 $0 $0 $7,315 $0 $7,315
FTA Penalty $0 $0 $0 $0 $0 $0

 

Violation Items
# Citation ID Citaton Type Standard Issuance Date Abatement Due Date Current Penalty Initial Penalty Contest Latest Event Note
1. 01001 Serious 19100132 F02 06/24/2022 07/21/2022 $7,315 $7,315   I – Informal Settlement Citation has been deleted.
2. 01002 Other 19100147 C04 I 06/24/2022 07/21/2022 $7,315 $7,315   I – Informal Settlement  

 

Source: https://www.osha.gov/ords/imis/establishment.inspection_detail?id=1577453.015

 

 

 

 

 

 

Scroll to Top