Stored energy can be LETHAL

On November 3, 2020, at 1:15 p.m., Employee #1, 55, employed by an HVAC company, was working at a customer’s commercial facility.

He was removing a coupler and blind from the intake header of an air dryer.

The employee did not first relieve the air pressure from the header.

When he loosened the coupler bolts, the coupler and blind were propelled off the header by the pressure release.

The flying parts struck employee #1.

Employee #1 sustained blunt force traumatic injuries and was killed.

Violations/PenaltiesSeriousWillfulRepeatOtherTotal
Initial Violations3  14
Current Violations3  14
Initial Penalty$28,398$0$0$0$28,398
Current Penalty$28,398$0$0$0$28,398
#Citation IDCitaton TypeStandard CitedIssuance DateAbatement Due DateCurrent PenaltyInitial PenaltyLatest Event
1.01001Serious19100147 C04 I04/30/202105/24/2021$13,653$13,653Z – Issued
2.01002Serious19100147 C07 I A04/30/202105/24/2021$6,144$6,144Z – Issued
3.01003ASerious19100147 D0304/30/202105/24/2021$8,601$8,601Z – Issued
4.01003BSerious19100147 D04 I04/30/202105/24/2021$0$0Z – Issued
5.01003CSerious19100147 D0604/30/202105/24/2021$0$0Z – Issued
6.02001Other19100147 F02 I04/30/202105/24/2021$0$0Z – Issued

Source: https://www.osha.gov/ords/imis/establishment.inspection_detail?id=1501662.015