Escape respirators have a SINGLE function:
to allow a person working in a normally safe environment sufficient time to escape from suddenly occurring respiratory hazards.
Given this function, selection does not rely on assigned protection factors. Instead, these respirators are selected based on:
- a consideration of the time needed to escape, and
- the likelihood of IDLH or oxygen deficiency conditions.
Escape respirators can be separated into two (2) categories: