Emergency Response

Emergency Responders and Fit Testing

In the USA, OSHA REQUIRES employers to “Fit Test” each worker who will wear a tight-fitting respirator.  This includes all types of tight-fitting respirators, from half-face air purifying respirators to full-face supplied air respirators.  The workers are also REQUIRED to be fit tested with EACH MAKE, MODEL STYLE and SIZE face piece they are medically qualified and […]

Wind Socks… a critical piece of Equipment?

It is pretty common for PSM/RMP facilities to have a windsock or two on-site.  However, the condition of these devices ranges from brand new to a piece of wire sticking up in the wind.  In this posting, I want to offer some tips on how we should manage our windsocks as a “piece of critical

1984 Mexico City BLEVE (1984)

At approximately 05:35 hours on 19 November 1984 a major fire and a series of catastrophic explosions occurred at the government owned and operated PEMEX LPG Terminal at San Juan Ixhuatepec, Mexico City. As a consequence of these events some 500 individuals were killed and the terminal destroyed. Three refineries supplied the facility with LPG

911 Call – 28-year old killed by forklift

This taped 911 call is being provided for others to learn from.  Many of us think that dialing 911 and effectively communicating with the emergency dispatcher needs no training.  This call may convience us that we need to train those who would be tasked with this critical link to the emergency responders.  Imagine that it

How NOT to respond to an Ammonia Leak!

Some responders would tell you this was a “sucessful response”.  They stopped the leak and did not injury anyone in the effort; however, it is not too difficult to identify several things these responders could have done differently in their response.  Can you identify them?  How many did you identify?

Anhydrous Ammonia Pipeline Rupture

  Accident No.: DCA05-MP001 Type of System: Hazardous liquid Accident Type: Pipeline rupture and leak with vapor cloud Location: 6 miles west of Kingman, Kansas Date: October 27, 2004 Time: 11:15 a.m. central daylight time Owner: Magellan Midstream Partners, L.P. Facility: Magellan Ammonia Pipeline/Enid Lateral Operator: Enterprise Products Operating L.P. Fatalities/Injuries: None Damage/Clean-up Cost: $680,715 Material

Oxygen Depletion in Level A Hazmat Suits

UPDATED on 6/23/2017   This study was conducted in conjunction with the Faculty of the Undergraduate College of Integrated Science and Technology, James Madison University, Virginia; the Harrisonburg (VA) Fire Department; and the Harrisonburg (VA) Rescue Squad HRS.  Although not done as a true research study, it was done as well as could be expected

Scroll to Top