Acetylene Cylinder Safety

Many people do not know that acetylene cylinders are constructed differently than regular compressed gas cylinders. They contain a porous material and acetone, in which the gas dissolves and becomes practically stable. The porous filler absorbs the acetone and eliminates large voids in which decomposition might occur. Store and use these cylinders in an upright […]

Guidance for Conducting Risk Management Program Inspections under Clean Air Act Section 112(r)

EPA is announcing the release of “Guidance for Conducting Risk Management Program Inspections under Clean Air Act Section 112(r)” (EPA 550-K-11-001, January 2011).  This document updates and supersedes the “Guidance for Auditing Risk Management Plans/Programs under Clean Air Act Section 112(r)” of August 1999.  The new document includes updated EPA policy on involvement of facility

LOPA and SIS/SIL

LOPA is a Layer of Protection Analysis and is a type of PHA that looks at the actual layers of protection a particular scenario would have. As you know, process safety is built upon the fundamental concepts of prevention, threat, and mitigation. Hence, we want to prevent the scenario from even starting, but if we

Interesting EU Dust Explosion Stats

Every year an estimated 2000 dust explosions occur in factories and refineries in Europe. There are approximately 50 reported dust explosions in the UK alone – that’s roughly one every single week. But these explosions are not solely the preserve of chemical or wood processing companies.  A staggering 24 per cent of them occur within

NFPA’s Dust Standard 654 is REVISED for the 2011 edition

NFPA 654 provides a framework from which to address combustible dust hazard identification and control. Currently developed by the Committee on Handling and Conveying of Dusts, Vapors, and Gases, NFPA 654 prescribes a step-by-step approach, beginning with characterizing the properties of the combustible particulate solid. These steps form the core requirements of the standard and

BLENDED BREATHING AIR FATALITIES

Two workers lost their lives when the supplied breathing air cylinders they were breathing from contained low levels of oxygen. The two workers were working on top of a scaffold, sandblasting the interior of a boiler. A third worker was outside the entry to the boiler to make sure the breathing lines did not become

HOAX – Crosby Counterfeit Shackle Alert

E-mail from VP @ Crosby: I have uploaded the two documents he refers to in his e-mail to my LinkedIn Profile. Please see the attachments regarding the counterfeit alerts that have been circulating recently. The Crosby Group, Inc. has prepared a letter addressing the issue, and also has received a clarification letter from the OSHA

Model: JLG LIFT 600AJ – INTERNAL RUST IN BOOM SECTION

Model: JLG LIFT 600AJ During a prestart inspection it was noticed that water was leaking out of rivets on the top boom section near the basket, upon closer inspection was found that a drain hole was block and approximately 300mm of water was retained inside the boom section. The drain hole was unblocked and the

Non-conductive Flammable Liquids & Filters

If you have a non-conductive flammable liquid and you are passing them through a filter, the hazard associated with static electricity generation can be up to 300X greater. This actually goes with any type of obstruction in the pipe/hose (orifice plate, partly opened valve, flow probe, etc). If you must have a filter/strainer in your