CLICK HERE to Renew your Membership
CLICK HERE for a NEW Membership
CLICK HERE to see eligibility requirements for FREE Membership
If you have any questions, please contact me

I am proud to announce that SAFTENG and The Chlorine Institute have renewed our partnership for another year (through 2026).  Members of The Chlorine Institute receive a FREE SAFTENG membership.  If you qualify, please contact me

NOTE: Any trade group interested in becoming a partner with SAFTENG for your Member Companies, please reach out, and I can share the plan

SAFTENG has:

Many THANKS to my NEW Members and those who CONTINUE to support SAFTENG:

Since 2012
Since 2025
Since 2010
Since 2008
Since 2026
Since 2026
OneDigital | Resourcing Edge Since 2026
Since 2015
Since 2010
Since 2024
Since 2008
since 2012
Since 2024
Since 2010
OH Fire Code and Ammonia Refrigeration as of 12/15/2017
As of yesterday (12/15/2017), the state of Ohio has a new fire code, which just happens to be a revised version of the 2015 International Fire Code.  As I have been writing about this year, this revised code could have an impact on a number of businesses/industries.  For example, ammonia refrigeration processes that are built from this day on will NO LONGER be permitted to discharge their...
Read More
c3cddc5e
2017 Photo of the Week #51 (Ladders, scaffolding, hi-vis vests, camera)
Read More
2017 Video of the Week #51 (Compressed Gas Cylinder falls over and launches)
 
Read More
Compressed air used for cleaning and "effective chip guarding"
Out of 250 inspections in 2016 where this was looked at, 1910.242 was cited 253 times for $589,704.  For something so simple, that is some crazy money!!!  So what does 1910.242(b) require: Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective...
Read More
Safety Data Sheets and NFPA 704/HMIS labeling information
When OSHA adopted the UN’s Globally Harmonized System of Classification and Labelling of Chemicals (GHS) workplaces probably saw the biggest change in workplace safety that we have seen since the PSM standard.  One of the biggest changes came with the new Safety Data Sheet (SDS) format and for some reason, many “responsible parties” felt the need to no longer include NFPA...
Read More
Workplace Labels (sometimes called secondary, internal or in-house labels) under OSHA's GHS
One of the biggest myths of OSHA compliance over the past four years is that NFPA 704 and/or HMIS are no longer valid “secondary container” labels and that these “secondary containers” labels must contain pictograms, signal word, precautionary statements, etc. Companies and businesses have been sold a pile of @#$%! in order to spend millions of dollars on label makers and new...
Read More
OSHA issues Willful and Serious after triple fatality flash fire at car dealership service bay ($152K)
OSHA has cited an Alabama automobile dealership for serious safety violations after three employees died and two were injured at its Jasper facility. OSHA initiated an investigation in response to a flash fire. Inspectors determined that the employees were using a flammable brake wash to scrub the service pit floor when the fire occurred. As a result, three employees were fatally injured, and a fourth...
Read More
EPA RMP citations @ Pork Processing Plant (NH3 & $49K, w/ SEP $62K)
Respondent operates a pork processing plant with the following two (2) covered anhydrous ammonia refrigeration systems at the stationary source: Main System; and Auxiliary System Respondent has exceeded the threshold quantity for ammonia (anhydrous) at the Main System and the Auxiliary System.  On or about August 19, 2014, and March 30, 2015, EPA conducted an inspection of the Respondent’s...
Read More
Fire Code Validation - DOUBLING Storage amounts per control area
I am working on a code evaluation project, and the client had a different interpretation (more strict) that I did so I reached out to the Ohio Fire Marshal to settle the discussion.  The question arose as to how much flammable solid(s) can one store without having to raise the occupancy classification to an “H.” TABLE 307.1, Maximum allowable quantity per control area...
Read More
2018 IFC changes in HAZMAT piping requirements
2018 is just around the corner and with it’s arrival comes the 2018 International Fire Code (IFC) and some changes.  For those in the process safety arena or just storing/handling/processing hazardous materials, Chapter 50 Hazardous Materials, is a valuable resource for the design of piping systems conveying those hazardous materials.  In 2018 IFC there are some changes to sections...
Read More
Line Break/Process Opening GONE BAD (NH3)
This incident involved issues with LOTO and PPE with the line break/process opening.  OSHA issued citations against 1910.111, .147, .134, and .1200. At 4:00 p.m. on March 13, 2017, in preparation of a new pump arriving, a worker started draining lines leading to a 30,000-gallon liquid anhydrous ammonia tank. After the tank had been drained, the worker started loosening the bolts that held the...
Read More
water proof electric
2017 Photo of the Week #50 (No worries, that is Water Proof Electrical )
Read More