Let us help you make sense of PSM / RMP! 

My friend Brian Chapin will be offering an open-enrollment PSM/RMP class in Burleson, Texas, July 8th to 11th, 2025. Brian is an absolute pro in NH3 Refrigeration Process Safety. Anyone who attends will also get a FREE membership to SAFTENG. You can get more information on the class with this link. 

CLICK HERE to Renew your Membership
CLICK HERE for a NEW Membership
CLICK HERE to see eligibility requirements for FREE Membership
If you have any questions, please contact m

SAFTENG has:

Many THANKS to my NEW Members and those who CONTINUE to support SAFTENG:

Since 2015
Since 2007
Since 2012
Since 2025
Since 2005
Since 2015
Since 2009
Since 2012
since 2025
Since 2025
Since 2025
Since 2025
Since 2021
Since 2025
A piping reference change from 2018 to 2021 IFC (B31 to B31.1)
I have asked for a formal response regarding this change, which was NOT noted in the 2021 edition as a change; however, it is a change in text and application. In the 2018 edition, Chapter 50 stated: Piping, tubing, valves, and fittings conveying hazardous materials shall be designed and installed in accordance with ASME B31 or other approved standards, and shall be in accordance with Sections 5003.2.2.1...
Read More
Backflow prevention and check valves where hazardous materials could create a hazardous condition
If you are a regular visitor to this site, you know I love to use the International Fire Code, which many states adopt in full or in some “revised” langauge as their “state fire/hazmat code”.  One particular item that garners a lot of questions and comments is the IFC’s requirement that ALL hazardous materials (those with toxic or physical hazards) be in piping constructed...
Read More
2 entrants and 2 would-be-rescuers (VFD) in residential well
This is another example of entrants not recognizing the space they are entering is a CONFINED SPACE and the actions/work they did turned the confined space into a PERMIT-REQUIRED CONFINED SPACE.  Both entrants died and two (2) volunteer FF’s were injured in their attempts to perform rescues at this residential incident. On May 26, 2010, @ approximately 8:15 pm, worker #1, a licensed plumber,...
Read More
Nitrogen (pneumatic) pressure testing fatality
On May 11, 2023, @ 8:04 a.m., an employee working for an oil and gas support services company was found dead. On May 10th, the night before, the employee had instructed his coworkers from other contractors to go home, and he would finish the job. This was the last time anyone had spoken to the employee until he was found deceased. The employee had been pressure testing a pipe with nitrogen. …...
Read More
Employee Is Killed In Ammonia Overexposure
This fatal incident displays the CRITICAL role of having procedures for responding to leaks, even “small releases.”  1910.119(n) Emergency planning and response The employer shall establish and implement an emergency action plan for the entire plant in accordance with the provisions of 29 CFR 1910.38. In addition, the emergency action plan shall include procedures for handling small...
Read More
Celebrating "blink luck" is dangerous
Many organizations had a great 2023 in terms of their safety performance.  And while I am a huge advocate for celebrating our successes in safety, my support is contingent on one factor… KNOW HOW we achieved our success.  Celebrating blind luck is dangerous! Organizations often celebrate sheer luck in safety performance, which sends the wrong message to everyone.  To ensure it...
Read More
OSHA issues PRCS citations @ environmental and emergency services company (O2 Deficiency & $118K)
OR-OSHA has fined a Portland environmental and emergency services company $118,800 for violating job safety standards designed to protect workers from the potentially deadly hazards of confined spaces. The division cited the employer following an inspection of an incident reported by Portland Fire & Rescue. Oregon OSHA’s July 14, 2023 incident inspection found that two members of a four-person...
Read More
FRC program - Laundering
Having spent my entire career in Flame Retardant Clothing, I learned that improper laundering could render the PPE useless, maybe even hazardous to wear.  In my time, we always had a contractor launder and maintain our FRC.  It was not cheap, but it was necessary to ensure the PPE worked as intended when we needed it most.  Today, we see a lot of “cost-saving” trends involving...
Read More
Difference between a hose's MAWP and it's "Burst Pressure"
To simplify this, the Maximum Allowable Working Pressure (MAWP) is the maximum pressure at which the hose can operate routinely.  Although, I strongly suggest the “operating ranges” be far less than the MAWP.  However, achieving the MAWP does NOT mean the hose will necessarily fail.  Where the hose will fail is called the “Burst Pressure.”  Usually, the safety...
Read More
VISION ZERO may not be all that bad when it takes this approach
I know this can be a sensitive topic, even though I am not a fan of the “Zero Harm” approach, but when it was presented like this, I have to say I support all seven (7) of these functions within a Safety Management System (SMS). VISION ZERO – 7 Golden Rules – for zero accidents and healthy work A guide for employers and managers … HomeRead More »
Read More
MI-OSHA updates its Fire Brigade standard to address PFAS containing foam concentrate or foam solution
R 408.17313 Proper use, handling, storage, and containment of firefighting foam concentrate. Rule 7313. … HomeRead More »
Read More
EPA issues RMP Program 2 citations @ fertilizer business (NH3 & $82K)
On or about January 31, 2023, representatives of the EPA inspected Respondent’s Facility to determine compliance with Section 112(r) of the CAA and 40 C.F.R. Part 68. Information gathered during the EPA inspection revealed that Respondent had over 10,000 pounds of anhydrous ammonia in a process at its facility. Information gathered during the EPA inspection revealed that Respondent stores, distributes,...
Read More