Pressure Safety Valve/Relief Valve Installation Failure

One of the top questions newcomers to process safety ask is, “Why do I have to have a written procedure to remove and install new relief valves?”From the EPSC Learning Sheet October 2024What Happened:The bonnet vent in a Balanced Bellows Pressure Safety Valve (BB-PSV) was found in service, but still fitted with a shipping plug. Internal leakage past the bellows would give back pressure, raising the set pressure above its design, so not protecting the equipment.The ANSWER…WRITTEN PROCEDURES and TRAINING to qualify those who will be executing said procedures. 1910.119(j)(2) Written procedures. The employer shall establish and implement written procedures to maintain the on-going integrity of process equipment. 68.73 Mechanical integrity.

(b) Written procedures. The owner or operator shall establish and implement written procedures to maintain the on-going integrity of process equipment. Source: https://mcusercontent.com/3b12c62c9e65ecb7f0c544b82/files/8d4b4cab-19b9-4e36-94c2-160a55d8719d/24.08_EPSC_Learning_Sheet_Balanced_Bellow_PSV.pdf?fbclid=IwY2xjawFxByZleHRuA2FlbQIxMAABHUozbaQCEwHCbYE0vjEEEPsRu2c4jzn8rpldoHflJmjDyqqDrFw19LzdLw_aem_5m9I4Sb3Ngm7s4cXED8H_g