Bryan Haywood

Contains any other RECOGNIZED SERIOUS SAFETY OR HEALTH HAZARD (SAFETY2019! Follow-Up)

As it usually goes, the vast majority of challenges and questions I have received thus far from yesterday’s ASSP2019! Presentation centered around the most controversial characteristic of 1910.146… 4. Contains any other recognized serious safety or health hazard I could have spent half a day talking about this single characteristic, but I had only 35 […]

OSHA PSM citations at Chemical Manufacturer For Exposing Workers to EO (EO & $262K)

OSHA cited a chemical manufacturer after a chemical release at the manufacturing plant exposed workers to ethylene oxide. The company faces $262,548 in penalties. OSHA initiated an inspection after the exposure hospitalized one employee and left five others suffering symptoms of ethylene oxide (EtO) exposure. The Agency cited 25 serious violations, including deficient emergency action

OSHA issues PSM citations to Host and Contractor after Fatal Fire at Natural Gas Processing Plant (Flammable Gas & $98K)

OSHA has cited the company contracted to clean lines and vessels at the plant and the processing plant for serious safety violations after a fatal fire at a natural gas processing plant in Pennsylvania.  OSHA inspected the company contracted to clean lines and vessels at the plant after four contractors suffered burns and needed hospitalization. One of

Vehicle Impact Protection Alternative to Bollards – Curb Barrier Protection Model

Anyone who works with SAFTENG knows we are serious about facility siting and more specifically VEHICLE IMPACT PROTECTION.  This stems from my horrible luck I had with vehicles around my covered processes.  I can not even remember how many incidents I suffered while a safety engineer in the petrochemical and semiconductor industries with everything from cranes

Accidents associated with ammonia (ARIA)

This study essentially concerns refrigeration installations using ammonia as a refrigerant.  However, in order to better understand and to place the risks associated with these installations in perspective, quantified information has also been collected on numerous accidents, both French or foreign, in other industrial or agricultural activities and in the field of transport. The processing of these data allows

Hydrogen chloride release following a maintenance operation

Ten kilos (22 pounds) of hydrogen chloride gas was released from a flange that had been fitted by a contractor just a few weeks earlier, triggering alarms and resulting in an internal emergency intervention. The incident had no significant consequences.  A contractor performing maintenance was instructed to remove the pressure sensor from a device and replace it with

Explosion of an underground solvent storage tank during a maintenance operation

A contractor at an upper-tier Seveso plant was cleaning an underground tank so that it could be filled with a different product. The tank was located in an outdoor area comprising 12 horizontal underground multi-compartment tanks, each having an overall capacity of 60 m³ (nominal compartment capacities of 10, 15 and 35 m³) and containing flammable liquids (solvents