Free

Requirements for our BULK Tranfer Hoses in a PSM/RMP Process

Recently, I had the opportunity to help a client gain the full picture of what has to be done regarding the BULK TRANSFER hoses to unload their HHC/EHS from Tanker Trucks/ISO Containers and Railcars. Now, before we get into the specifics, I know a number of folks will fall back on the compliance position that

Evacuating the Hazardous Materials to achieve a ZES can be more dangerous than the actual maintenance

Last week, David Ayers, Ph.D., CSP, CHMM, and I had a nice chat regarding LOTO and Complex Processes, and one of the areas associated with these LOTOs is the “evacuation” of the HAZMAT within the process/system. We did not have enough time for me to get deep into the weeds on this aspect of isolating

Static Electricty the cause of a Flash Fire destroying gasoline storage tank (Video)

An explosion at a large outdoor oil storage tank at Korea National Oil Corporation Pipeline’s Yeongnam branch is preliminarily attributed to static electricity generated during a petroleum component verification process. The incident occurred at a large-scale oil storage facility housing 12 to 14 tanks, raising concerns that it could have escalated into a major disaster.

PRCS Fatality (HAZ ATM benzene and toluene)

OSHA has cited a petroleum tank services contractor for exposing workers to chemical and respiratory hazards after an employee was fatally exposed to benzene and toluene when they entered a fuel storage tank in July 2025. Investigators cited the company with 12 serious violations for failing to develop and implement a written permit-required space entry

OSHA answers two (2) big questions about medical evaluations for Respirators

Question 1: To what extent does OSHA’s Respiratory Protection standard, at 29 CFR § 1910.134(e), require that the PLHCP’s medical evaluation for respirator use include consideration of factors beyond respiratory protection that affect fitness to safely perform the expected job tasks while wearing a respirator? Question 2: Is there a reasonable expectation that the employer

Line Break gone bad (Refrigerants)

OSHA has cited a Florida plumbing, heating, and air conditioning contractor for exposing workers to struck-by hazards after an employee suffered a fatal injury at a Bal Harbor Shops worksite in August 2025. OSHA found that on Aug. 28, 2025, a pipefitter installing a new air-conditioning system for a mall expansion construction project was fatally

Line Break gone Bad (HF Acid – CCPS Beacon 03/26)

I have written about this incident a couple of times, as it is full of learning opportunities. The biggest of which is the practice of REDUCING PPE after the initial opening was uneventful, and we have “verified” our positive means of isolation is holding. This is a common practice for long-duration jobs and plays a