Safety Info Posts

A2L Flammable Refrigerants are coming (IFC Code)

HIGHER FLAMMABILITY   A3 R-50, R-170, R-290 R-600a, R-441a, R-1270 B3 R-1140 LOWER FLAMMABILITY   A2 R-142b, R-152a B2 R-30, R-40, R-611, R-717     A2L HFO-1234yf, HFO-1234ze NO FLAME PROPAGATION   A1 R-11 – R-14, R-22, R-113, R-114, R-115, R-134A, R-410A, R-449B, R-1234zd B1 R-10, R-21, R-123, R-764   LOWER TOXICITY HIGHER TOXICITY  

20 COMMON FIRE CODE VIOLATIONS CHECKLIST

A state Fire Marshal published their Top 20 Violations.  Many of these are learning opportunities:   Building Exterior Address – Address numbers should be plainly visible from the street side of the property. Fire Lanes – Fire lanes are designated by the Fire Code Official. Signage for fire lanes must contain the verbiage in the

Fatality @ chicken processing plant confirms the application of 1910.145 and 1910.212 (OSHRC)

A chicken business processes poultry on two machines called eviscerators at its Mississippi facility. On May 31, 2021, an employee tasked with cleaning chicken parts and viscera from the eviscerators and areas around them suffered fatal injuries when he was caught in one of the machines. Following an inspection and investigation by Compliance Safety and

Total Recordable Injury Rate (TRIR) calculation flaw – Don’t drink the Koolaid!

As 2023 draws to an end, businesses across this great nation will be tallying their injury rates for bragging rights compared to other business locations, competitors, etc.  It is a 50+ year tradition for many of these businesses.  However, I wonder if this tradition would continue if they genuinely understood how flawed their calculation is. 

CPSC Proposes Rule to Establish Safety Standard for Residential Gas Furnaces and Boilers

On October 25, 2023, the U.S. Consumer Product Safety Commission (CPSC) published a proposed rule to establish a safety standard for residential gas furnaces and boilers. In the proposed rule, CPSC announces its preliminary determination that these products pose an unreasonable risk of injury and death. Therefore, CPSC’s proposed rule would require all residential gas

Managing Risks from trichloroethylene (TCE)

In October 2023, EPA proposed to ban the manufacture (including import), processing, and distribution in commerce of TCE for all uses, with longer compliance timeframes and workplace controls (including an exposure limit) for some processing and industrial and commercial uses until the prohibitions come into effect. The rule would protect consumers, workers, occupational non-users and

Types of Information Relevant for Response Planning

The Risk Management Program emergency response coordination activities require the owner and operator of a stationary source to provide to the local emergency planning and response organizations: the stationary source’s emergency response plan if one exists; emergency action plan; updated emergency contact information; and any other information that local emergency planning and response organizations identify