Don’t say it is “locked out” when the isolation devices on the energy soures are NOT locked in their safe positions

At 8:00 a.m. on March 15, 2021, Employee #1 removed, cleaned, prepared the surface and replaced the blow-in door gasket seals on the USS McFaul. The door was TAGGED OUT in the OPEN position; however, in this position, the pneumatic pressure and electric power could NOT be secured in its SAFE POSITION. While performing the work, the door closed on the employee, crushing her. She died from the resulting traumatic asphyxiation and cardiac arrest.

Violation Summary
  Serious Willful Repeat Other Total
Initial Violations 1       1
Current Violations 1       1
Initial Penalty $9,557 $0 $0 $0 $9,557
Current Penalty $6,690 $0 $0 $0 $6,690
FTA Amount $0 $0 $0 $0 $0

 

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ LastEvent
1. 01001 Serious

19150089 G01 – Before servicing machinery, equipment, or a system

that has a lockout/tags-plus system; the employer shall ensure that

the authorized employee or the primary authorized employee in a

group lockout/tags-plus application verifies that the machinery,

equipment or system is de-energized, and all energy sources isolated.

09/15/2021 10/12/2021 $6,690 $9,557 I – Informal Settlement
 
 
 

 