OSHA’s proposed WERE and ESO Facility Preparedness requirements

Proposed paragraph (i) provides requirements to ensure that Workplace Emergency Response Employers (WEREs) facilities are safe for team members. Paragraph (i)(1)(i) of the proposed rule would require WEREs to ensure their facilities comply with 29 CFR 1910 Subpart E, Exit Routes and Emergency Planning.  This proposed provision is not a new requirement because WEREs are already required to comply with Subpart E. It is included here to reinforce the concept that compliant means of egress, emergency lighting, exit marking, etc., are of the utmost importance during emergency situations for all workers, but especially for team members because they spend more time in dangerous situations.

For instance, an obstructed aisle or hallway could interfere with removing a sick or injured non-team-member employee by means of a wheelchair or ambulance cot. That same obstructed aisle or hallway could delay firefighting team members in reaching a fire, thus allowing the fire to grow, further endangering the team members, or blocking their escape path if they need to evacuate due to deteriorating conditions.

Many responders spend a significant amount of time in the workplace, often sleeping and eating meals there because they are required to be at the ESO facility to
respond to emergency incidents quickly. While responders expect to encounter hazards at an emergency incident, they may also become injured or ill from hazards they are exposed to in ESO facilities. Proposed paragraph (j) provides requirements to ensure that ESO facilities are safe for responders.

The proposed Facility Preparedness requirements for WEREs and Emergency Service Organizations (ESOs) include:

Proposed paragraph (i)(1)(ii) would require Workplace Emergency Response Employers (WEREs) to provide facilities for the decontamination, disinfection, cleaning, and storage of PPE and equipment.

Cleaning and decontamination of PPE and equipment is an important step in reducing or preventing exposure to bloodborne pathogens, carcinogens, and other contaminants which can cause cancer and other illnesses in team members and responders. The proposed requirement would ensure that team members have a means to decontaminate, disinfect, and clean their PPE and equipment as needed and as required by proposed paragraph (k). These requirements are based on NFPA 1581, Standard on Fire Department Infection Control Program, 2022 ed., and NFPA 1851, Standard on Selection, Care, and Maintenance of
Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, 2020 ed.

The manner of compliance with this provision could vary depending on a WERE’s facility, the activities of the WERT, and the manufacturer’s instructions for particular PPE and equipment. Some WEREs may provide a dedicated room or area with commercial style washing machines or extractors for PPE. Others may only provide
facilities for basic cleaning and gross decontamination using a utility hose and brushes, a large sink with spray nozzle, appropriate cleaning chemicals and disinfectants, and drying racks. Alternatively, if PPE is to be decontaminated or disinfected at another location, such as an off-site commercial launderer, WEREs would need to provide for bagging and storage of contaminated PPE while it is still at the WERE facility, to prevent exposure to employees and team members, and prevent cross contamination with clean PPE. 

 

Proposed paragraph (i)(1)(iii) would require the WERE to ensure that fire detection, suppression, and alarm systems, and occupant notification systems are installed, tested, and maintained in accordance with manufacturer’s instructions and 29 CFR 1910 Subpart L – Fire Protection.

WEREs are already required to comply with Subpart L. Cross-referencing this provision in the proposed rule serves as a reminder to WEREs and reinforces the importance of these requirements in the context of a WERT, where proper operation of these systems during a fire emergency could affect the safety of team members.

 

Proposed paragraph (i)(2) would require the WERE to ensure fire hose connections and fittings are compatible with, or adapters are provided for, firefighting infrastructure such as fire hydrants, sprinkler system and standpipe system inlet connections, and fire hose valves (FHV), to facilitate prompt firefighting support from mutual aid WERTs and ESOs.

A majority of fire hose fittings and connections, with varying diameters, use a standard hose screw thread dimension. However, other screw thread dimensions are available and used for fire hose connections and fittings, including non-threaded connections. While OSHA believes it would be advantageous to have uniformity of all screw threads, it is more important that the fitting diameters, screw threads, and nonthreaded connections at the facility are compatible with those used by the WERT(s) and ESO(s) who would potentially provide firefighting support. Any delay in providing needed fire suppression water to a sprinkler system or standpipe system could result in a fire spreading and thus endangering or further endangering team members (as well as other employees at the facility). The inability to connect hoses from a fire engine to the inlet connections due to noncompatible screw treads or fitting diameter would certainly cause a delay in providing needed fire suppression water. 

OSHA’s existing standard for standpipe and hose systems, 29 CFR 1910.158, requires standardized screw threads or adapters for hose connections (29 CFR 1910.158(c)(2)(ii)) for quick connection of fire hoses. The existing provision applies within the employer’s facility but fails to take into consideration the need for potential support from mutual aid WERTs or ESOs. Additionally, the current provision predates the development of nonthreaded connections for large diameter fire hoses, which are sometimes used for sprinkler and standpipe inlet connections and fire hydrant fittings.

The proposed provision would ensure mutual aid WERTs and ESOs, as required by proposed paragraph (c)(8) of this section, could provide needed water supply without delay, thus reducing the potential risk to team members, non-team member employees, and responders.  To provide added clarity and as noted elsewhere in this preamble, OSHA proposes in this rulemaking to revise 29 CFR 1910.158, Standpipe and hose systems, and 29 CFR 1910.159, Automatic sprinkler systems, to add a provision for system inlet fitting compatibility with, or adapters provided for, mutual aid WERTs and ESOs, consistent with paragraph (i)(2) of this proposed rule.

 

Proposed paragraph (i)(3) would require WEREs to identify the location of each fire hose valve (FHV) in a manner suitable to the area, such as with a sign, painted wall, or painted column, to ensure prompt access to FHVs.

The proposed provision excludes FHVs visible on standpipes in enclosed stairways. Compliance with this provision could be achieved by various methods, including marking the location of each FHV with a sign, painted wall, painted column, or other suitable means that would ensure that each FHV is visible, thus making the FHV easier to locate during an emergency. This approach is particularly important in facilities with large open areas, such as parking garages, plant manufacturing areas, and storage rack areas, where FHVs may otherwise be difficult to locate, especially during an emergency.

 

Paragraph (j) ESO Facility Preparedness

Many responders spend a significant amount of time in the workplace, often sleeping and eating meals there because they are required to be at the ESO facility to
respond to emergency incidents quickly. While responders expect to encounter hazards at an emergency incident, they may also become injured or ill from hazards they are exposed to in ESO facilities. Proposed paragraph (j) provides requirements to ensure that ESO facilities are safe for responders.

 

Proposed paragraph (j)(1)(i) states that the ESO must ensure each ESO facility complies with 29 CFR 1910 Subpart E – Exit Routes and Emergency Planning.

This proposed provision is not a new requirement because ESOs are already required to comply with Subpart E. It is included here to emphasize the necessity of safe means of egress, emergency lightning, exit marking, etc., during emergency situations.

 

Proposed paragraph (j)(1)(ii) would require the ESO to provide facilities for decontamination, disinfection, cleaning, and storage of PPE and equipment.

As discussed in Need for the Standard, responders are exposed to a variety of hazardous substances from contaminated PPE and equipment. Cleaning and decontamination of PPE and equipment are important steps in reducing or preventing exposure to carcinogens, infectious diseases, and other contaminants which can cause other illnesses. This provision also aids compliance with proposed paragraph (k)(2)(viii), which would require the ESO to ensure that protective ensembles, ensemble elements, and protective equipment are decontaminated, cleaned, cared for, inspected and maintained in accordance with the manufacturer’s instructions (see the Summary and Explanation for paragraph (k)).

The manner of compliance with proposed paragraph (j)(1)(ii) would vary depending on an ESO’s facility and manufacturers’ instructions. However, basic cleaning
and gross decontamination typically involves using a utility hose and brushes, a large sink with a spray nozzle, appropriate cleaning chemicals and disinfectants, and drying racks. Some ESOs may choose to install commercial-style washing machines or extractors for PPE. Alternatively, if PPE is to be decontaminated off-site, ESOs must provide for bagging and storage of contaminated PPE while it is still at the ESO facility.

 

The requirements proposed in paragraph (j)(1)(ii) are based on NFPA 1581, Standard on Fire Department Infection Control Program, 2022 ed., and NFPA 1851,
Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, 2020 ed.

 

Proposed paragraph (j)(1)(iii) would establish requirements for fire poles, slides, and chutes.

 

Under proposed paragraph (j)(1)(iii)(A), the ESO would need to ensure each responder who uses a fire pole maintains contact with the pole using all four extremities and is not holding anything other than the pole. Sliding down the pole is essentially a controlled fall, and maintaining contact with all four extremities offers the best chance for responders to control their speed while descending the pole. Ensuring the responder does not hold anything while using the pole would help them focus on the importance of gripping the pole and would avoid potential distraction such as spilling a cup of coffee or dropping a handful of papers.

 

Proposed paragraph (j)(1)(iii)(B) would require the ESO to ensure that each fire pole has a landing cushion that is at least 30 inches in diameter, has a contrasting color to the surrounding floor, and has impact absorption to reduce the likelihood and severity of injury.

The minimum diameter requirement is meant to accommodate responders of varying shapes and sizes. The contrasting color would enhance visibility to the potential
tripping hazard on the floor. The landing cushion would also need to be made of a material with sufficient thickness to reduce the impact of a responder landing on the
cushion.

 

Proposed paragraph (j)(1)(iii)(C) would require ESOs to ensure that each floor hole with a fire pole, chute, or slide that provides rapid access to a lower level is secured or protected in accordance with 29 CFR 1910 Subpart D – Walking-Working Surfaces to prevent unintended falls through the floor hole.

Given the importance of these requirements in addressing the hazard posed by these floor openings in ESO facilities, OSHA believes it is important to remind ESOs of their obligations under Subpart D to reinforce compliance. The trend in the design and construction of new ESO facilities is to install slides, chutes, and stairs as an alternative to installing new fire poles.

Paragraph (j)(1)(iv) of the proposed rule would require the ESO to ensure that fire detection, suppression, and alarm systems, and occupant notification systems are installed, tested, and maintained in accordance with manufacturer’s instructions and 29 CFR 1910 Subpart L – Fire Protection.

Fire protection systems are important for protecting responders from the danger of fire in ESO facilities. They must function properly to provide protection. Following the manufacturer’s instructions for installing, testing, and maintaining this equipment will help to provide this protection because the instructions are tailored to deal with the unique features of a particular manufacturer’s equipment. The last part of this provision serves as a reminder to comply with Subpart L, which contains specific requirements to ensure the effectiveness of various types of fire detection, suppression, and alarm systems.

Proposed paragraph (j)(2)(i) would require the ESO to ensure that interconnected hard-wired smoke alarms with battery back-up are installed inside each sleeping area, and outside in the immediate vicinity of each opening (door) to a sleeping area, and on all levels of the facility, including basements. Smoke detectors that are integral to a fire alarm system would also satisfy this proposed provision. Smoke alarms and detectors provide early warning about the presence of smoke, thus alerting occupants to the hazard and need for evacuation before they are overcome by smoke inhalation and typicaly
before the fire grows to the point of preventing escape.

 

Proposed paragraph (j)(2)(ii) would require the ESO to ensure that each new ESO facility with one or more sleeping area(s) is protected throughout by an automatic sprinkler system.

This provision would apply to new facilities constructed (as determined by the date of building permit issuance) two years or more after the final rule is
published. It has long been established that automatic sprinklers save lives. They provide containment or extinguishment of a fire, often before those endangered by the fire are aware of the fire, particularly for those who are asleep. Automatic sprinkler systems are routinely installed in many places where people sleep, such as hotels, motels, dormitories, apartment buildings, and single-family dwellings. OSHA believes it is important for ESOs to provide the same protection for responders. The proposed rule provides ample time for ESOs in the preliminary planning process of designing new facilities to include the installation of sprinklers.

Proposed paragraph (j)(2)(iii) would require the ESO to ensure that each sleeping and living area has functioning carbon monoxide alarms installed.

Similar to smoke alarms/detectors, carbon monoxide alarms alert occupants to the presence of the poisonous gas, thus allowing them to evacuate before they become incapacitated. The risk of carbon monoxide exposure may be high for responders because ESO vehicle engines are started and run inside of ESO facilities.
Proposed paragraph (j)(2)(iv) would require the ESO to prevent responder exposure to, and contamination of sleeping and living areas by, exhaust emissions. OSHA
believes that compliance with this provision can be achieved by any of several means, including direct or source capture systems attached to vehicle exhaust pipes, automatic ventilation systems, positive air pressure in sleeping and living areas, self-closing doors with weather seals, and others.

Paragraph (j)(2)(v) of the proposed rule would require the ESO to ensure that contaminated PPE is not worn or stored in sleeping and living areas.

This provision, in conjunction with proposed paragraphs (j)(1)(ii) (decontamination, disinfection, cleaning, and storage facilities) and (k)(2)(viii) (decontamination and cleaning of PPE), would ensure that responders are not unnecessarily exposed to contaminants in sleeping and living areas.

 