CLICK HERE to Renew your Membership
CLICK HERE for a NEW Membership
CLICK HERE to see eligibility requirements for FREE Membership
If you have any questions, please contact me

I am proud to announce that SAFTENG and The Chlorine Institute have renewed our partnership for another year (through 2026).  Members of The Chlorine Institute receive a FREE SAFTENG membership.  If you qualify, please contact me

NOTE: Any trade group interested in becoming a partner with SAFTENG for your Member Companies, please reach out, and I can share the plan

SAFTENG has:

Many THANKS to my NEW Members and those who CONTINUE to support SAFTENG:

Since 2012
Since 2025
Since 2010
Since 2008
Since 2026
Since 2026
OneDigital | Resourcing Edge Since 2026
Since 2015
Since 2010
Since 2024
Since 2008
since 2012
Since 2024
Since 2010
LPG leak at flange during Start-Up (DMIR)
An operator at a liquefied petroleum gas (LPG) processing facility heard a loud noise coming from an area of the plant during start-up, following significant maintenance works. The operator identified that high pressure, flammable natural gas was being released to the atmosphere from a localized point beneath the insulation of process equipment. The Department of Fire and Emergency Services (DFES)...
Read More
EPA RMP Citations @ Ethanol facility (NH3 & Flammables & $73K w/ a $209K SEP)
Respondent owned, leased, operated, controlled or supervised a facility for ethanol fuel production. Respondent conducted activity involving anhydrous ammonia at the Facility, including using, storing, handling or moving on-site anhydrous ammonia ( anhydrous ammonia process). Respondent conducted activity involving a flammable mixture that included natural gas condensates (flammable mixture) at the...
Read More
Fake e stop
2018 Photo of the Week #26 (E-STOPs need Functional Testing)
Read More
2018 Video of the Week #26 (Cutting open vessel... explosion)
I am trying to find information on this incident.  OSHA could not be more clear on this tasks: General Industry 1910.252(a)(3)(i) Used containers. No welding, cutting, or other hot work shall be performed on used drums, barrels, tanks or other containers until they have been cleaned so thoroughly as to make ABSOLUTELY CERTAIN that there are no flammable materials present or any substances such...
Read More
UPDATE: 2018 Video of the Week #25 (Butane sphere BLEVE!)
NEW video added at the bottom, shows tank collapsing into pool fire and many other angles and close-ups. In March of 2011, a magnitude 9.0 earthquake and subsequent tsunami devastated the Tohoku area of Japan.  This disaster included some of the most significant BLEVE type failures of LPG spheres ever recorded, at the Chiba refinery near Tokyo. Fireball diameters of greater than 200 m (650′)...
Read More
improper tagout
2018 Photo of the Week #25 (Tagout... not quite!)
Read More
34,000 pounds of NH3 released over a month results in $664,190 EPCRA and CERCLA citations
At all times relevant to this Complaint, Respondent owned and operated buildings, structures, installations, equipment, pipes or pipelines, and storage containers, located on a single site or on contiguous or adjacent locations, where it deposited, stored, disposed of,  or placed, Ammonia CAS# 7664-41-7.  Ammonia CAS# 7664-41-7 was a “hazardous substance” as that term was defined...
Read More
Shelter-In-Place means a RMP Update is due in 6-months
Recently a facility had an NH3 release via an RV and in the spirit of “doing it right” made all the necessary calls, including notifying their local FD.  The FD arrived, although it was not required as the facility response team had matters under control before their arrival, the FD felt it was necessary to issue a SIP alert for those within 1,000′ of the facility.  This...
Read More
Process Operators and "Emergency Response"
Employees such as chemical process operators may be required to shut down processes, close emergency valves and otherwise secure operations that are not in the hot zone or danger area before evacuating in the event of an emergency. (See 29 CFR 1910.38(a)(2)(ii).) These procedures need to be delineated carefully, and employees must be trained to be able to perform these pre-evacuation procedures safely....
Read More
c60ea
2018 Photo of the Week #24 (More of "Smoking is hazardous to your health")
Read More
2018 Video of the Week #24 (LPG is not to be played with!)
Read More
Car-Seal Program (Revised 6/2018)
For SAFTENG members… I have revised my Car-Seal Program to incorporate the “attendance requirements” for deviated valves. … HomeRead More »
Read More
1 350 351 352 353 354 756

Partner Organizations

Member Associations

Scroll to Top