What is an approved self-closing valve?

This week I posted the requirement for transferring a flammable liquid using “gravity”.  This requirement comes from OSHA’s flammable liquid standard… 1910.106(e)(2)(iv)(d) flammable liquids shall be drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through

EPA RMP GDC citations @ windshield wiper fluid manufacturing facility (Methanol & $197K)

PLEASE NOTE this case is significant in that many facilities in the OSHA arena will EXEMPT their “methanol” from PSM coverage using the “Atmospheric Storage Tank” exemption (e.g. 1910.119(a)(1)(ii)(B) or called the “Meer Decision”).  EPA couldn’t care less about this OSHA exemption, as is evident in this case! There is NO EPA RMP exemption for flammable liquids stored

OSHA clarifies the 6-month testing frequency of Rubber Insulating Electrical Gloves (1910.137)

One of the more common deficiencies that we find in our audits is the lack of electrical gloves testing.  1910.137, Table I-5 establishes the testing frequency for these gloves; however, the confusion comes with the “footnote” which states… If the insulating equipment has been electrically tested but not issued for service, the insulating equipment may not

EPA RMP citations @ LPG and Butane facility

Respondent owns and operates a liquefied petroleum gas plant which handled and handles a maximum of approximately 3,548,000 pounds of propane and 761,400 pounds of butane at the Facility. EPA conducted an inspection of the Facility on October 17, 2018 to determine Respondent’s compliance with CAA Section 112(r)(l) and (7) and the Chemical Accident Prevention

Benchmarking Risk by Whole Room Scale Leaks and Ignitions Testing of A3 Refrigerants

The objective of this project was to conduct refrigerant R-290 (propane) leak and ignition testing under whole room-scale conditions to develop data and insight into the risks associated with the use of Class A3 Refrigerants and to generate technical data to support revisions of relevant safety standards.       The entire project included parametric testing

When the Condenser manufacturer is telling you their equipment is a Permit-Required Confined Space

This week I was at one of my food clients who use anhydrous ammonia as their refrigerant.  This client replaced two old condensers with one bigger condenser. This new condenser came with some interesting labels, which to safety professionals, made our “assessment” of this piece of equipment relatively easy… it is a Permit-Required Confined Space. 