Free

Why does the IFC 2024 Flammable Liquids Chapter (57) reference ASME B31.9 for leak testing rather than B31.3?

NOTE: If you’re in an INDUSTRIAL facility, especially one with a PSM/RMP-covered process, B31.9 is NOT your piping RAGAGEP! IFC 5703.6.3 dictates that piping for flammable and combustible liquids must be hydrostatically tested to 150% of the maximum anticipated pressure (or pneumatically tested to 110%). However, it offers a carve-out: “Unless tested in accordance with […]

Refinery fined £1 million after major gas leak

Structural collapse caused the release of around 2,400kg of highly flammable liquid petroleum gas.HSE investigation found that long-standing corrosion of the steel tower was not dealt with.Workers exposed to the risk of serious injury and burns in a major incident. The refinery has been fined £1 million after a major gas leak following an investigation

Catastrophic LPG Loading Failure leads to Explosion claiming 10 lives (Video)

The Chain of Failure The catastrophe centered on the unloading area for liquefied petroleum gas (LPG) tanker trucks and unfolded over a matter of minutes. Botched Connection: Around 1:00 a.m., a driver attempted to connect an omnidirectional loading arm to the tanker’s discharge outlet. The connection procedure was complex, and the driver failed to secure

OSHA’s ability to use the GDC at facilities that fall under the PSM TQ

OSHA uses the General Duty Clause (GDC), Section 5(a)(1) of the OSH Act as a “gap filler” to cite employers for recognized chemical hazards when a specific standard (like the Process Safety Management standard, 29 CFR 1910.119) does not technically apply. There are some critical legal limitations on GDC Enforcement: OSHA’s ability to invoke 5(a)(1)

Can OSHA issue 5(a)(1) citations when a process is under its PSM TQ?

Apparently, they can and have. Here are some GDC citations for an NH3 refrigeration process. These were part of a large release inspection that included some HAZWOPER and HAZCOM citations. My only guess is that these GDC citations are tied directly to the NH3 release, but I have not yet seen the field notes, so

NFPA updates its 704, Standard System for the Identification of the Hazards of Materials for Emergency Response

The 2027 edition of the standard includes new definitions for the terms battery energy storage system and lithium-based battery with associated annex material. Updates have been made in Section 6.2 to align with NFPA 1 regarding 1A and 1B flammable gases and to further clarify that Category 1B has a lower flammability than Category 1A

What is a Hierarchy of Controls Analysis (HCA)?

A Hierarchy of Controls Analysis (HCA) is a highly structured risk-mitigation methodology. It is specifically required under CalARP Program 4, which applies to petroleum refineries operating within California. While a standard Process Hazard Analysis (PHA) identifies risks and lists existing safeguards, an HCA forces a facility to systematically evaluate whether hazards can be eliminated or

Scroll to Top