Free

EPA RMP Citations @ chemical manufacturing facility (Anhy NH3/>20% NH3 & $40K w/ $157K SEP)

Respondent operates a chemical manufacturing facility which has on-site for use, 25,299,678 pounds of anhydrous ammonia and 355,094 pounds of ammonia (concentration 20% or greater). Respondent has two RMProgram level 3 covered processes, that store or otherwise use anhydrous ammonia and ammonia (concentration 20% or greater) in amounts exceeding their applicable thresholds of 10,000 pounds […]

CSB Issues Final Report on Toxic HF Incidents at Geismar, Louisiana Facility

Today, the CSB released its final report addressing three (3) serious chemical incidents involving toxic hydrogen fluoride (HF) at a facility in Geismar, Louisiana. The incidents occurred over a period of less than three years, from October 2021 to June 2024, and reveal systemic safety failures at the facility. These incidents were LOPC events, two

Defining RAGAGEPs for Process Safety Management (Rand Study)

Process safety management (PSM) is a suite of risk management elements designed to minimize the risk of accidents associated with industrial processes using highly hazardous materials. The California Division of Occupational Safety and Health (Cal/OSHA) PSM regulation requires that process equipment and equipment inspection and testing adhere to recognized and generally accepted good engineering practices

Changes to states/counties with “Delegated RMP Enforcement”

The current list of delegated states and counties is: Additionally, the following territories and local jurisdictions have delegation: Kentucky, Puerto Rico, and the Virgin Islands NO LONGER implement the program and the Regional office has taken over implementation for those areas. Florida has a partial delegation (everything but propane facilities) North Dakota has a partial

The first documented case of static electrical ignition of a household substance causing facial burns (NIH 2019)

A 60-year-old female worker in a plastic moulding workshop was cleaning a large plastic bin. The bin had been vacuum cleaned and then sprayed with ‘Ambersil’, a highly flammable mould-removing aerosol spray that can be purchased for domestic use. The patient attempted to wipe the bin, but when she placed her face inside it to

Adhesive use inside ductwork causes a fatal Hot Work fire ($156K)

At 10:00 a.m. on November 13, 2024, Employee #1 (23) was inside a large section of HVAC duct applying Design Polymerics DP 2590 Duct Liner Spray Adhesive to repair sagging insulation. After completing the adhesive application, Employee #1 used a pin welder to secure the insulation. While using the welder, a spark ignited flammable vapors