Elevated Line-Break goes BAD
On February 28, 2020, an employee, 36, was tasked with replacing a gasket in a 6-inch bolted flange on top of the Platformer Heater at an Oil Refinery. The employee was working in a man basket on top of the Platformer Heater. The employee loosened the bolted flange while using hand tools to remove a…...