Hazardous Materials

Storing Ammonium Nitrate in Ohio

There has been much written about the Ammonimum Nitrate (AN) stored at the West Fertilizer facility in West, TX.  The investigation is still on-going; however, investigators have confirmed that AN was stored on site and it is their leading suspect in the explosion that killed a dozen emergency responders.  Last week the media focus shifted […]

Increased Civil Penalties Take Effect for Those Who Knowingly Violate Federal Hazmat Laws and Regulations

The U.S. Department of Transportation’s Pipeline and Hazardous Materials Safety Administration (PHMSA) has announced that the increased maximum civil penalties for safety violations of Federal hazardous materials transportation law and the regulations issued under that law that lead to death, serious injuries or extensive property damage are now in effect. The increased penalties are being

UNLOADING HAZMAT to the wrong tank (CL2 Incident)

Many safety and process safety professional think incidents like this are “rare”.  They would be wrong, unless of course their definition of “rare” is a bit looser than mine!  I do not have official numbers of the frequency of this type of incident but I am trying to obtain them and will certainly pass them

Pipeline Safety: Reporting of Exceedances of Maximum Allowable Operating Pressure

PHMSA is issuing this Advisory Bulletin to inform owners and operators of gas transmission pipelines that if the pipeline pressure exceeds maximum allowable operating pressure (MAOP) plus the build-up allowed for operation of pressure-limiting or control devices, the owner or operator must report the exceedance to PHMSA on or before the fifth day following the

NEW DOT Shipping Papers REQUIREMENT EFFECTIVE 1/1/13

Effective January 1, 2007, PHMSA adopted a shipping description sequence consisting of identification number first, followed by the proper shipping name, hazard class or division number, and packing group (e.g., UN1133, Adhesives, 3, PG II).  This new shipping description sequence is mandatory on shipping documents prepared according to the International Civil Aviation Organization’s Technical Instructions

The DOT 25′ Attendant Rule

One problem that seems to run wild across all businesses is DOT’s “25 feet and in line of sight” rule for unloading/loading hazardous materials.  Just this year (September & November 2012) the Pipeline and Hazardous Materials Safety Administration issued LOIs on the matter, reaffirming their expectation in regards to this rule.  The letters stated…

Flammable Liquid (and COM DUST) piping “flange jumpers”

In processes handling flammable liquids, “flange jumpers” (also known as “bonding jumpers”) are critical safety components designed to maintain electrical continuity across piping joints. Since piping systems are often coated, gasketed, or subject to corrosion, a standard flanged connection may not provide a sufficiently low-resistance path to ground.

Update on Cl2 release @ Poultry Plant

The Centers for Disease Control released a report today saying that a Tyson poultry plant worker who poured a solution into a 55-gallon drum, releasing chlorine gas, could not read the English label on the drum that would have alerted him to its contents, but Tyson disputes the findings.

Scroll to Top