Safety Info Posts

EPA RMP citations @ repackaging facility (Cl2, SO2, Flammables & $261K)

Respondent is the facility’s owner and operator. The EPA inspected the Facility from July 27 to July 29, 2021, to determine the Respondent’s compliance with Section 112(r) of the CAAmand 40 C.F.R. Part 68 (“the Inspection”).  Operations at Respondent’s Facility include, among others, repackaging chlorine for utilization in sodium hypochlorite bleach manufacturing. The Facility also

Pressure Testing piping with N2 turns fatal

At 8:04 a.m. on May 11, 2023, an employee working for an oil and gas support services company was found dead. On 5/10/23, the night before, the employee had instructed his coworkers from other contractors to go home, and he would finish the job. This was the last time anyone had spoken to the employee

Fire Watch dies from burns

On October 16, 2023, Employee #1 worked for a construction gas & oil support contractor. Coworkers were cutting and welding an eye-lifting plate on a compressor skid. Miscellaneous petroleum products had been allowed to accumulate on, in, and around the compressor skid area, creating a fire hazard.

Is pressure and leak testing required after maintenance or alterations on piping systems?

It is good that we are finding fewer and fewer facilities without pressure testing and leak testing records on their process piping.  But now comes the difficult question: Is pressure and leak testing required after maintenance or alterations on piping systems? So, most companies will have their newly installed piping pressure tested and leak tested

The simple path to implementing SIF

In the world of industrial safety, we are not at a loss for the desire to try new things. Many consulting companies are waiting to sell us their shiny gadgets. One of these latest crazes is called “SIF”—Serious Injuries and Fatalities. The concept behind this model is based on the progress many have made in

CFAT Impacts on EPCRA and RMP

The Department of Homeland Security’s Chemical Facility Anti-Terrorism Standards (CFATS) impose comprehensive federal security regulations for high-risk chemical facilities. Do the CFATS alter the requirements that apply to a facility covered under both CFATS and either the Emergency Planning and Community Right-to-Know Act (EPCRA) or the Clean Air Act §112(r) (i.e., the Risk Management Program