Employee Is Killed In Ammonia Overexposure

This fatal incident displays the CRITICAL role of having procedures for responding to leaks, even “small releases.”  1910.119(n) Emergency planning and response The employer shall establish and implement an emergency action plan for the entire plant in accordance with the provisions of 29 CFR 1910.38. In addition, the emergency action plan shall include procedures for […]

Celebrating “blink luck” is dangerous

Many organizations had a great 2023 in terms of their safety performance.  And while I am a huge advocate for celebrating our successes in safety, my support is contingent on one factor… KNOW HOW we achieved our success.  Celebrating blind luck is dangerous! Organizations often celebrate sheer luck in safety performance, which sends the wrong

OSHA issues PRCS citations @ environmental and emergency services company (O2 Deficiency & $118K)

OR-OSHA has fined a Portland environmental and emergency services company $118,800 for violating job safety standards designed to protect workers from the potentially deadly hazards of confined spaces. The division cited the employer following an inspection of an incident reported by Portland Fire & Rescue. Oregon OSHA’s July 14, 2023 incident inspection found that two

FRC program – Laundering

Having spent my entire career in Flame Retardant Clothing, I learned that improper laundering could render the PPE useless, maybe even hazardous to wear.  In my time, we always had a contractor launder and maintain our FRC.  It was not cheap, but it was necessary to ensure the PPE worked as intended when we needed

EPA issues RMP Program 2 citations @ fertilizer business (NH3 & $82K)

On or about January 31, 2023, representatives of the EPA inspected Respondent’s Facility to determine compliance with Section 112(r) of the CAA and 40 C.F.R. Part 68. Information gathered during the EPA inspection revealed that Respondent had over 10,000 pounds of anhydrous ammonia in a process at its facility. Information gathered during the EPA inspection

Go ahead, tell me I’m crazy… but an FRC uniform provider/laundering contractor is a PSM/RMP contractor

In 2023, I began taking issue with the condition of Flame Retardant Clothing (FRC) being used in REQUIRED areas and tasks.  We see garments that in no way would pass a “routine inspection” per NFPA limitations.  My go to RAGAGEP for this is NFPA 2113, Standard on Selection, Care, Use, and Maintenance of Flame-Resistant Garments