FATAL Pressure Test (BSEE Alert)

On May 15, 2021, an incident resulted in the fatality of an offshore worker when two production personnel were pressure testing a 16-inch well surface casing and anexplosion occurred. The explosion entailed a high-pressure release with no signs of ignition.  Information obtained by BSEE during the subsequent investigation determined that personnel were using a high-pressure […]

EPA issues RMP citations @ liquid natural gas pretreatment process (Flammable & $163K)

Respondent has a liquid natural gas pretreatment process at the Facility, meeting the definition of ” process” as defined by 40 C.F.R. § 68.3. Respondent receives natural gas by pipeline and pretreats the natural gas to remove carbon dioxide, sulfur compounds, water, mercury, and heavy hydrocarbons. The regulated substance under 40 C.F.R. Part 68 Chemical

2024 safety resolutions… Written Program Specifics

On New Year’s Eve, I hope many safety pros will choose a 2024 resolution to end the regurgitation of OSHA standards as their “written programs.” I have always used the OSHA standard as my baseline, but these programs need to EXPLAIN HOW the facility will meet the requirements – not repeat the requirements. For example…

Safety Tip… its not the air that is the hazardous energy source; its what the air moves that creates the hazard

One thing that many find confusing regarding the control of hazardous energy is the actual hazard they are trying to render to a Zero Energy State (ZES).  This is a simple concept, but many get it wrong in their programs and machine-specific procedures.  Let’s take compressed air as an example.  Many compressed air systems in

Fire extinguisher fails during pressure testing

What happened? The extinguisher, rated to 2900 psi was being tested to a pressure of 4351 psi. The incident occurred when the test pressure reached 2842 psi. The extinguisher was 13 years old. No one was harmed. The failure occurred under test conditions, and no personnel were nearby to be injured. The hydrostatic test was

Periodic Inspections should be SIMPLE and straightforward

Lockout is a life-critical program/process/procedure(s). Our efforts to VERIFY that the program/process/procedures meet our needs is a CRITICAL path in the LOTO process.  OSHA recognized this when it promulgated its Control of Hazardous Energy standard (1910.147).  Specifically, 1910.147(c)(6) “Periodic Inspections” requires the employer to verify the program/procedures and that the employees can properly apply them

What does it mean when our facaility is a “High-hazard Group H occupancy”

High-hazard Group H occupancies are characterized by an unusually high degree of explosion, fire, or health hazard compared to typical commercial and industrial uses.  There is one common feature about Group H occupancies—they are designated as Group H based on excessive quantities of hazardous materials within the facility/building. Where the quantities of hazardous material stored