Maintenance requirements for leased tanks
 I use propane as a raw material in my manufacturing process. I lease the tank from the propane supplier. The supplier does all the maintenance. My staff never work on the equipment. What should I do? … HomeRead More »
Read More
States with authority to implement / enforce the risk management program rule
Which states have been granted a delegation of EPA’s authority to implement and enforce the risk management program rule? … HomeRead More »
Read More
What is the definition of a "technically qualified individual"?
Certain exemptions may apply to determine whether more than a threshold amount of a regulated substance is present at a stationary source under 40 CFR Part 68. One exemption is for regulated substances that are “manufactured, processed, or used in a laboratory at a stationary source under the supervision of a technically qualified individual as defined in §720.3(ee) of this chapter” (40...
Read More
After a reportable accident, do I have to revise my RMP?
I recently submitted my five-year RMP update required by section 68.190 (b)(1) and included my accident history for the previous five years. Two months later, we had another reportable accident. Do I have to do anything to revise my RMP? … HomeRead More »
Read More
Who is responsible for preparing and submitting an RMP for leased propane tanks?
If an owner of a stationary source leases propane tanks from a gas supplier, who is responsible for preparing and submitting the risk management plan (RMP) addressing the propane tanks? … HomeRead More »
Read More
How does this active mitigation system affect my selection and analysis of an alternative release scenario?
I run a wastewater treatment plant that is subject to the risk management program regulations in 40 CFR Part 68 for a covered process containing chlorine. A chlorine scrubber system at the plant is designed to prevent any possible releases from reaching a toxic endpoint offsite. How does this active mitigation system affect my selection and analysis of an alternative release scenario? …...
Read More
Determining frequency of ER coordination activities
The Risk Management Program regulations require owners and operators of stationary sources to coordinate their response needs annually, or more frequently if necessary, with local emergency planning and response organizations (40 CFR §68.93(a)). Are stationary sources responsible for determining if coordination activities should occur more often than annually? … HomeRead More »
Read More
RMP Records Maintained Onsite
Does the owner or operator have to maintain a written copy of the RMP on site at the stationary source? … HomeRead More »
Read More
Are Mechanical Controls Considered Administrative Controls?
To analyze the worst-case release scenario required as part of the hazard assessment at 40 CFR Part 68, Subpart B, the worst-case release quantity is identified as the greatest amount held in a single vessel or pipe, taking into account administrative controls that limit the maximum quantity (40 CFR §68.25(b)). Are mechanical controls such as alarms considered administrative controls and therefore...
Read More
How close must a stationary source be to a weather station in order for that station's data to be applicable to the stationary source?
How close must a stationary source be to a weather station in order for that station’s data to be applicable to the stationary source? … HomeRead More »
Read More
What is EPA's criteria for selecting stationary sources to audit?
The implementing agency will, according to the regulations at 40 CFR §68.220(b), select stationary sources for audits based on any of the following seven (7) criteria: … HomeRead More »
Read More
"Safety Competence" matters
Competence is defined in ISO 45001:2018, 3.23, as “the ability to apply knowledge and skills to achieve intended results”. Competence enables a person or organization to act effectively in a job or situation. It is acquired through training, education, experience, or a combination of these, as determined by the organization. Workers whose activities affect or can affect an organization’s OH&S performance,...