CLICK HERE to Renew your Membership
CLICK HERE for a NEW Membership
CLICK HERE to see eligibility requirements for FREE Membership
If you have any questions, please contact me

I am proud to announce that SAFTENG and The Chlorine Institute have renewed our partnership for another year (through 2026).  Members of The Chlorine Institute receive a FREE SAFTENG membership.  If you qualify, please contact me

NOTE: Any trade group interested in becoming a partner with SAFTENG for your Member Companies, please reach out, and I can share the plan

SAFTENG has:

Many THANKS to my NEW Members and those who CONTINUE to support SAFTENG:

Since 2008
Since 2026
Since 2012
Since 2008
Since 2026
Since 2026
OneDigital | Resourcing Edge Since 2026
Since 2015
Since 2010
Since 2024
Since 2026
since 2012
Since 2024
Since 2010
OSHA issues Corporate Wide Settlement Agreement to Grain Handling Company
OSHA and a grain handling company have signed a comprehensive settlement requiring the company to implement safeguards, training, and audit procedures at its 20 grain handling facilities in six states. The agreement resolves contested citations issued by OSHA in April 2012 after six individuals were killed and two injured as a result of an Oct. 29, 2011, explosion at the Atchison grain elevator. Under...
Read More
Screen Shot 2017 12 19 at 3.24.03 PM
Refrigeration Safety Study - Ammonia Incidents in British Columbia (BC) 2007 - 2015
The Safety Authority of British Columbia (BC) has released a case study of all refrigerant leaks in BC from 2007 to 2015. The study breaks down: Number of Refrigeration Units by Refrigerant and Safety Classification The Boilers, Pressure Vessels and Refrigeration (BPVR) Incident Investigations Refrigeration Incidents by Refrigerant Ammonia Releases by Facility Type Ammonia Releases at Arenas...
Read More
Limitations of Emergency Escape Respirators
Escape respirators have a SINGLE function: to allow a person working in a normally safe environment sufficient time to escape from suddenly occurring respiratory hazards. Given this function, selection does not rely on assigned protection factors.  Instead, these respirators are selected based on: a consideration of the time needed to escape, and the likelihood of IDLH or oxygen...
Read More
Escape-only respirators and your Emergency Response Plan
Employers may provide ESCAPE-ONLY respirators to those whose ONLY action is to leave the area immediately and take NO part in the response. Escape-only respirators MUST be NIOSH-approved and appropriate for the potential airborne concentration and class of substances specified in the employer’s hazard determination (1910.134(d)). Emergency escape-only respirators must be inspected BEFORE being...
Read More
A respirator medical evaluation is NOT an emergency responder fitness-for-duty evaluation
A fairly common mistake we see at facilities that have their own emergency response teams is that the responders are NOT receiving a fitness-for-duty evaluation and only receiving the same medical evaluation as those who wear respirators in non-emergency settings.  This is a problem, as OSHA has stated that emergency responders need more than the basic respirator medical evaluation.  Here...
Read More
Screen Shot 2017 12 17 at 8.08.46 PM
Choosing the proper Fit Test protocols based on the respirator type and usage
Fit testing is required for ALL employees using negative or positive pressure tight-fitting respirators, where OSHA requires such respirators or where the employer requires the use of such a respirator. A fit test is NOT required for voluntary users or escape-only respirators. (NOTE:  SCBA’s are NOT escape-only respirators.)  The fit test must be performed before the respirator is used in the...
Read More
Using Respirator Mobile Test Units for Medical Clearances, PFTs, and Fit Tests
Over the past several years we have seen an increase in the use of mobile test units for respiratory medical clearances and fit testing.  Most safety professionals have seen these type of mobile units.  When done correctly, these mobile units can save a lot of time and thus save the employer a lot of money; unfortunately, most of these mobile units create serious compliance issues in their...
Read More
4101 2 11 01 ph ff n ru 20170526 1429 1
OH Mechanical Code Update (11/2017)
The state of Ohio updated it’s Mechanical Code as it applies to “Refrigeration” in November 2017.  Here are the updates: … HomeRead More »
Read More
OH Fire Code and Ammonia Refrigeration as of 12/15/2017
As of yesterday (12/15/2017), the state of Ohio has a new fire code, which just happens to be a revised version of the 2015 International Fire Code.  As I have been writing about this year, this revised code could have an impact on a number of businesses/industries.  For example, ammonia refrigeration processes that are built from this day on will NO LONGER be permitted to discharge their...
Read More
c3cddc5e
2017 Photo of the Week #51 (Ladders, scaffolding, hi-vis vests, camera)
Read More
2017 Video of the Week #51 (Compressed Gas Cylinder falls over and launches)
 
Read More
Compressed air used for cleaning and "effective chip guarding"
Out of 250 inspections in 2016 where this was looked at, 1910.242 was cited 253 times for $589,704.  For something so simple, that is some crazy money!!!  So what does 1910.242(b) require: Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective...
Read More
1 379 380 381 382 383 760

Partner Organizations

Member Associations

Scroll to Top