Ā 

CLICK HERE to Renew your Membership
CLICK HERE for a NEW Membership
CLICK HERE to see eligibility requirements for FREE Membership
If you have any questions, please contact me

I am proud to announce that SAFTENG and The Chlorine Institute have renewed our partnership for another year (through 2026).Ā  Members of The Chlorine Institute receive a FREE SAFTENG membership.Ā  If you qualify, please contact me

NOTE: Any trade group interested in becoming a partner with SAFTENG for your Member Companies, please reach out, and I can share the plan

SAFTENG has:

Many THANKS to my NEW Members and those who CONTINUE to support SAFTENG:

Since 2008
Since 2026
Since 2012
Since 2008
Since 2026
Since 2026
OneDigital | Resourcing Edge Since 2026
Since 2015
Since 2010
Since 2024
Since 2026
since 2012
Since 2024
Since 2010
9f978d
2018 Photo of the Week #44 (Did we complete the fall protection training this month?)
Read More
2018 Video of the Week #44 (When things go wrong, your training matters!)
This year I have shared several videos of flammable liquid transfers that were done badly with serious consequences.  To end the year on a positive note, this week’s video is one showing things going wrong and then the TRAINED WORKER steps in and uses his training to end the incident as well as could have been hoped for.  TRAINING MATTERS in PREVENTION, PROTECTION, and MITIGATION!
Read More
OSHA PRCS citations @ tanker cleaning company
OSHA has cited a tank cleaning company $171,281 in penalties for confined space, fire, and explosion hazards. OSHA inspectors determined that the company allowed employees to enter a tank without testing for atmospheric hazards. The company was cited for allowing employees to use a non-explosion proof vacuum in a tank that transported a highly hazardous chemical; failing to provide appropriate personal...
Read More
Contractor in a Chlorine Process - HAZCOM or PSM training and Fit-Testing needs? (OSHC)
This case involved a contractor working in a Chlor-Alkali Unit when there was a Cl2 leak.  Six of the contractors had to go to the hospital due to exposure to Cl2 due to their inability to evacuate up-wind.  There was a lot of factors in this case, but OSHA issued two citations: HAZCOM – as OSHA took issue with the “contractor safety training”, it was vacated Respirator...
Read More
Venting Requirements for "Inside Flammable Liquid Atmospheric Aboveground Storage Tanks (AST)"
A fairly common debate I have with folks is the “normal venting” and “emergency venting” requirements for “Inside Flammable Liquid Storage Tanks.” The bottom line…These tanks MUST be vented outside the building for normal and emergency venting, except for Class IIIB liquids. Tanks Inside Buildings (TINBIDS) requirements in Chapter 57 of the IFC become applicable...
Read More
Fernie Investigation- Findings & Recommendations for Refrigeration Contractors/Mechanics (Video Presentation)
This is a recording of a live session that took place on October 30, 2018. The session was intended for refrigeration contractors & mechanics. The following was covered: Key findings of the Fernie Investigation Recommendations from the Investigation that pertain to owners/operators of ammonia refrigeration plants Open question & answer period
Read More
Fernie Investigation- Findings & Recommendations for Refrigeration Contractors/Mechanics (Video Presentation)
This is a recording of a live session that took place on October 30, 2018. The session was intended for refrigeration contractors & mechanics. The following was covered: Key findings of the Fernie Investigation Recommendations from the Investigation that pertain to owners/operators of ammonia refrigeration plants Open question & answer period
Read More
OSHA submits RFI regarding computer-based controls of hazardous energy vs. traditional LOTO
Recent technological advancements that employ computer-based controls of hazardous energy (e.g., mechanical, electrical, pneumatic, chemical, and radiation) conflict with OSHA’s existing lock-out/tag-out standard. These computer-based controls have become more prevalent as equipment manufacturers modernize their designs. Additionally, national consensus standards and international standards harmonization...
Read More
OSHA LOI on the GHS HAZCOM standard
MSDSonline has shared their LOI from OSHA regarding 16 well-crafted questions they submitted to OSHA regarding the GHS HAZCOM standard. Some of OSHA’s answers may be a wake-up call for some businesses who “import” chemicals and most will be surprised by who is an “importer” in the eyes of OSHA. … HomeRead More »
Read More
Regional Emphasis Program for FGAN and Agricultural NH3 Facilities
OSHA’s Regional Emphasis Program (REP) to reduce injuries, illnesses and fatalities related to workers’ exposures in fertilizer grade ammonium nitrate (FGAN) and agricultural anhydrous ammonia mixing/blending, storage, and distribution facilities has some very focused items for those facilities that store, handle, and dispense NH3 (29 CFR 1910.111). The standard applies to all facilities...
Read More
hotwork safety
2018 Photo of the Week #43 (Hot Work, flammables, and combustibles)
1910.252(a)(2)(vii) Relocation of combustibles. Where practicable, all combustibles shall be relocated at least 35 feet (10.7 m) from the work site. Where relocation is impracticable, combustibles shall be protected with flameproofed covers or otherwise shielded with metal or asbestos guards or curtains.
Read More
2018 Video of the Week #43 (Another fire from improper transfer)
There is so much to learn from this video!  Transferring a flammable liquid using gravity without a dead-man valve is NOT allowed and for the reason shown below (they lost contents from BOTH totes!).  (See 1910.106(e)(2)(iv)(d) PROPER GROUNDING AND BONDING is an absolute MUST when transferring flammable liquids. (See 1910.106(e)(6)(ii) SPLASH FILLING should NEVER be permitted...