Hazardous Materials

Manual addition of powders to a flammable atmosphere (NFPA 77)

As I noted in 2007, the #1 cause of process vessel deflagrations is the manual additions of powders to process vessels which have a flammable atmosphere. NFPA 77 covers this hazard with several solutions, yet many facilities are either not aware of these risks and solutions or simply have their head buried regarding these catastrohic […]

“Switch Loading” injures worker

The definition of “switch loading: Switch loading is the hazardous practice of loading a low-vapor-pressure product (such as diesel or heating oil) into a tank compartment that previously contained a high-vapor-pressure, flammable product (such as gasoline) without first cleaning it. This creates a high risk of static electricity generation and explosion, as residual vapors can

Are we starting to see the need for basic Oxygen detection

We see many compressed gas cylinders of Asphyxiants in labs within large industrial facilities. We even see these labs increasing their quantities and moving to using Dewars (cryogenic liquid storage) to store their asphyxiants. These dewars are a massive game-changer, as both Liquid N2 and Liquid Ar have expansion ratios of 1:700 and 1:860, respectively.

Requirements for our BULK Tranfer Hoses in a PSM/RMP Process

Recently, I had the opportunity to help a client gain the full picture of what has to be done regarding the BULK TRANSFER hoses to unload their HHC/EHS from Tanker Trucks/ISO Containers and Railcars. Now, before we get into the specifics, I know a number of folks will fall back on the compliance position that

Evacuating the Hazardous Materials to achieve a ZES can be more dangerous than the actual maintenance

Last week, David Ayers, Ph.D., CSP, CHMM, and I had a nice chat regarding LOTO and Complex Processes, and one of the areas associated with these LOTOs is the “evacuation” of the HAZMAT within the process/system. We did not have enough time for me to get deep into the weeds on this aspect of isolating

Static Electricty the cause of a Flash Fire destroying gasoline storage tank (Video)

An explosion at a large outdoor oil storage tank at Korea National Oil Corporation Pipeline’s Yeongnam branch is preliminarily attributed to static electricity generated during a petroleum component verification process. The incident occurred at a large-scale oil storage facility housing 12 to 14 tanks, raising concerns that it could have escalated into a major disaster.

Line Break gone Bad (HF Acid – CCPS Beacon 03/26)

I have written about this incident a couple of times, as it is full of learning opportunities. The biggest of which is the practice of REDUCING PPE after the initial opening was uneventful, and we have “verified” our positive means of isolation is holding. This is a common practice for long-duration jobs and plays a