CLICK HERE to Renew your Membership
CLICK HERE for a NEW Membership
CLICK HERE to see eligibility requirements for FREE Membership
If you have any questions, please contact me

I am proud to announce that SAFTENG and The Chlorine Institute have renewed our partnership for another year (through 2026).  Members of The Chlorine Institute receive a FREE SAFTENG membership.  If you qualify, please contact me

NOTE: Any trade group interested in becoming a partner with SAFTENG for your Member Companies, please reach out, and I can share the plan

SAFTENG has:

Many THANKS to my NEW Members and those who CONTINUE to support SAFTENG:

Since 2008
Since 2026
Since 2012
Since 2024
Since 2026
Since 2026
OneDigital | Resourcing Edge Since 2026
Since 2015
Since 2010
Since 2024
Since 2026
since 2012
Since 2024
Since 2010
Two Kansas Companies Fined $1 Million Each In Atchison Chlorine Gas Case
Sorry, I have not seen any actual citations or details of how this incident occurred, but I will update if I get anything. A chemical supplier and an Ingredients’ facility have been fined $1 million each for violating the federal Clean Air Act when a cloud of toxic chlorine gas was released over Atchison, Kan., in 2016.  Both companies have paid the fines.  U.S. District Court Judge Daniel...
Read More
EPA RMP citations @ Refinery (Flammables & $?????)
I am not sure how much of the $4 million was for RMP, as there were other issues in this Consent Decree and I have only pulled out the RMP issues. On or about September 4, 2017, heater tube 23 ruptured in the CRU2/HTU2 charge heater process due to creep, a molecular failure mechanism that causes metal deformation as a result of stress from high temperatures. The rupture of heater tube 23 caused the...
Read More
Hand Sanitizer ALert VA OSHA
VA-OSHA Hazard Alert regarding hand sanitizer with 80% Alcohol
Last week, VA-OSHA posted this Hazard Alert regarding hand sanitizers with 80% alcohol.  Now I am not aware of any studies that differentiate the hazards of 80% versions from 70% and 65%% versions or of any incidents where static ignited the sanitizer when the user touched a grounded surface.  But we do know that Alcohols have Minimum Ignition Energies (MIE) less than 1 millijoule (mJ) and...
Read More
OSHA PSM citations @ chemical plant (Butadiene & $514K)
OSHA has cited a texas chemical company for exposing employees to workplace safety and health hazards after a fire and explosion at the plant in November 2019. The company faces $514,692 in fines. OSHA opened an investigation after vapor formed at the base of a butadiene finishing tower ignited and caused several explosions and fires. OSHA cited the facility for three willful violations for failing...
Read More
Determining frequency of emergency coordination activities (changes to response capabilities)
Today, the EPA’s RMP Info Center published the following guidance on the REVISED emergency coordination activities in the RMP Rule.  The Risk Management Program regulations require owners and operators of stationary sources to coordinate their response needs ANNUALLY, or more frequently if necessary, with local emergency planning and response organizations (40 CFR §68.93(a)). Are stationary...
Read More
Face Coverings, flame-retardant/resistant clothing (FRC) and hazardous locations
UPDATED 6/4/2020 with an FR face-covering item. (NOT an endorsement!) Westex UltraSoft® FR Face Mask 7oz. Westex UltraSoft® 88% Cotton / 12% High Tenacity Nylon Sizes: Regular Colors: Orange (OR) Style: FR9805 Source: https://rascofr.com/product-category/face-covering/ Last week the good folks are DuPont opened a can of proverbial worms that about a dozen of us have been hotly debating behind the...
Read More
Should we regress back to the basics?
Occupational safety used to be so simple and I believe we were better off then than where we are now.  When I started in the chemical industry in 1993, safety was a condition of employment.  What does that mean… you don’t follow the safety procedures and practices you will not be employed at the facility!  With OSHA’s PSM standard came a very formal “employee...
Read More
Hand Sanitizer Did this
Have you seen this picture and story? (Hand Sanitizer car fire)
Have you seen this yet?  If not, you most likely will either via your social media activity or by e-mail.  This week this picture and various stories about what happened have gone “viral” after a Wisconsin Fire District posted it on their FB Account as an attempt to educate their followers.  The “shares” are over 6K as of this morning and it is now being circulated...
Read More
Safety leaders and cultural responsibilities
Today I read in the news that a Police Chief of a metropolitan area announced his resignation amid a lot of turmoil in the city and within his Department.  And in the news story, I was taken back by the Metro Council President… “If the officers don’t feel in tune with their police chief, it displays itself on the street. And so, I think it’s very important for the police...
Read More
Table 105.6.10
Liquid Nitrogen and the IFC (Part I)
This week, we saw OSHA issue two willful and three serious violations totaling $122,602 to a sperm bank for bulls (cattle) after an employee was asphyxiated while filling freezers with Liquid Nitrogen.  And back in 2017, we saw another sperm bank, this one for humans, have a Nitrogen incident which claimed the life of a Deputy Sheriff and critically injured the supervisor of the business.  I have personally...
Read More
OSHA HAZ COM citiations after Nitrogen asphyxiation fatality
I am sharing this citation as Nitrogen (N2) use is becoming more and more popular in businesses that often times may not have the level of safety necessary to store and handle this level of hazardous materials.  I have personally seen N2 being used in personal grooming services and microbrewing and now this was a bull “stud” facility where I am guessing they were freezing the sperm. ...
Read More
Requirements for when rooms or buildings exceed the maximum allowable quantity per control area for flammable liquids
5705.3.7 Rooms or buildings for quantities exceeding the maximum allowable quantity per control area.Where required by Section 5705.3.5.3 or 5705.3.6.1, rooms or buildings used for the use, dispensing, or mixing of flammable and combustible liquids in quantities exceeding the maximum allowable quantity per control area shall be in accordance with Sections 5705.3.7.1 through 5705.3.7.6.3. …...
Read More
1 283 284 285 286 287 766

Partner Organizations

Member Associations

Scroll to Top